Skip to content
INFRA ATLASby Walter Strategy

Modul 4 / 6 · Finance · 15 min read

Business case and financing

← Learning path

Goal of this module

You can model a project and know what a bank wants to see.

The four key figures

  • Investment: everything, turnkey – system, installation, metering, grid connection.
  • Annual surplus: revenue minus operating costs (maintenance, insurance, metering).
  • Payback: after how many years the money invested is back.
  • Net present value: what the project is worth today when future surpluses are discounted at a hurdle rate. Positive means it beats the alternative investment.

Model honestly

In the example business of our guide (250 MWh consumption, 100 kWp PV, example assumptions), no battery option is clearly profitable at a 6% discount rate; the smallest comes close with a payback of about 11 years. Your real numbers decide: a cheaper quote, a higher demand charge, extra market revenue.

Always model at least two scenarios – a cautious one and an expected one. Grid fees change, market spreads shrink.

Common mistakes

  • Standard load profile instead of real metering data – one example shows 64% self-consumption by profile but only 42% with real data.
  • Forgetting to subtract the lost feed-in tariff.
  • Adding up revenues as if there were no conflicts.
  • Using last year's grid fees.

Financing

Three building blocks: equity, bank loan, promotional loan. KfW supports renewable power systems and batteries with its programme “Erneuerbare Energien – Standard (270)”, applied for via your bank. Always check funding programmes before placing the order.

A bank wants to see plausible assumptions with sources, written quotes, the grid operator's response – and whether annual surpluses safely cover the loan instalment. In project finance this figure is the debt service coverage ratio (DSCR). Clarify depreciation and VAT with your tax adviser in advance.

Exercise

Enter the numbers from module 1 and the size from module 3 into the storage calculator. Note payback and annual result for a cautious and an expected scenario.

Tools on INFRA ATLAS

Sources

  1. [1]KfW – Erneuerbare Energien – Standard (270), Unternehmen· accessed 2026-11-29
  2. [2]Solarserver – Gewerbespeicher: Acht häufige Fehler bei der Wirtschaftlichkeitsberechnung (01.04.2026)· accessed 2026-11-28
  3. [3]vbw – Leitfaden Stromspeicher für Unternehmen (Sep 2025)· accessed 2026-11-28

Editorial orientation, not investment, tax or legal advice. As of November 2026.

Let's talk about your plans.

Site, storage, data center or new markets for your components – write to us and we will get back to you personally.